Your Shopping Cart:

Your cart is empty

Product Image 1
  • Product Image 1

Replacement Power Head L37-501 (Mfg. #555-050RP)

Description:

The silent operation permits installation in or near rooms where noiseless operation is essential Heavy bronze body with sweat or threaded connections For heat pump and geothermal applications, Taco offers L37-906, which has corrosion-resistant internal parts designed to close against high head pumps (150′ head); 24VAC, 60 Hz, 0.9A rating L37-906 is a geothermal valve that eliminates water hammer L38-555 is the replacement head for L37-906

Description: Replacement Head; Mfg. #: 555-050RP;

Price: $159.99

Replacement Power Head L37-501 (Mfg. #555-050RP):

Description: The silent operation permits installation in or near rooms where noiseless operation is essential Heavy bronze body with sweat or threaded connections For heat pump and geothermal applications, Taco offers L37-906, which has corrosion-resistant internal parts designed to close against high head pumps (150′ head); 24VAC, 60 Hz, 0.9A rating L37-906 is a geothermal valve that eliminates water hammer L38-555 is the replacement head for L37-906 Description: Replacement Head; Mfg. #: 555-050RP;

  • Item Price: $159.99
  • Listed On: April 03, 2012

Price: $159.99

Share This Item:

Shopping Cart

You have 0 items in your shopping cart. View Cart

How Can We Help?

Contact Form:
* (denotes required field)

Featured Products

  • Unit Bearing Fan Motor S88-703 (Mfg# ESP-L16EMR2)

    Unit Bearing Fan M...

    Description: 16W,  shaded pole, 1500 RPM, CCWOSE rotation, 3-25/32″ diameter, 230V A: 3-3/8″; Agency Certification: UR/CSA; Diameter: 3-25/32″; Enclosure: TE; F/L Amps: 0.40; Hz: 60; Mfg. #: ESP-L16EMR2; Mounting: Rigid Base; Phase: Single; Rot.: CCWOSE; RPM: 1500; Service Factor: 1.00; Shaft Diam.: 1/4″; Shaft Length: 1/2″; Speeds: 1; Type: Shaded Pole; Volts: 230; Watts: 16;

  • Mojave Series Condenser Fan Motor S81-132 (Mfg# 1874H)

    Mojave Series Cond...

    Description: 48 frame, 825 RPM  PSC motor, reversible rotation, all-angle mounting  TEAO enclosure, class F insulation — thermal endurance to over 300°F  Ball bearings  48″ leads Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 70; Bearing Type: Ball; Capacitor to Match: G21-930; Diameter: 5-5/8″; Efficiency: 60.4%; Enclosure: TEAO; F/L Amps: 2.1; HP: 1/4-1/8; Hz: 60; Insulation Class: F; Mfg. #: 1874H; Mounting: Stud; NEMA Frame: 48; Phase: Single; Rot.: Rev.; RPM: 825; Service Factor: 1.00; Shaft Diam.: 1/2″; Shaft Length: 6″; Speeds: 1; Std. Mount. Pos.: All Angle; Thermal Protection: Auto; Type: PSC; Volts: 208-230; Wt. Lbs.: 13.0;

  • Electronically Commutated Motor S59-278 (Mfg# 22617701)

    Electronically Com...

    Description: ECM motor lowers operational costs through 50% increase in efficiency over shaded pole and PSC motors 1625 RPM; CCW rotation Diameter: 5/16″; Evaporator Type: Low Profile; HP: 1/15; Mfg. #: 22617701; Rot.: CCW; RPM: 1625; Volts: 208/230;

  • Electronically Commutated Motor S59-277 (Mfg# 22617801)

    Electronically Com...

    Description: Quick and easy solution for reducing costs and environmental impact without having to replace entire system Replacement motors lower operational costs through 50% increase in efficiency — or more — over shaded pole and PSC motors Easy-to-install as drop-in replacement; also available as an option on new Bohn, Larkin, Climate Control, and Chandler equipment Diameter: 5/16″; Evaporator Type: Low Profile; HP: 1/15; Mfg. #: 22617801; Rot.: CCW; RPM: 1625; Volts: 120

  • Unit Bearing Fan Motor S88-046 (Mfg# D562)

    Unit Bearing Fan M...

    Description: 51 frame, 9W, 1550 RPM Sleeve bearing, CWOSE rotation All-angle mounting, shaded pole, 1-speed Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 40; Bearing Type: Slv; Efficiency: 28.0%; Enclosure: TE; F/L Amps: 0.80; Hz: 60; Insulation Class: B; Mfg. #: D562; Mounting: All Angle; NEMA Frame: 51; Phase: Single; Rot.: CWOSE; RPM: 1550; Service Factor: 1.00; Speeds: 1; Thermal Protection: Auto; Type: Shaded Pole; Volts: 115; Watts: 9;

  • Unit Bearing Motor S55-311 (Mfg# 65311)

    Unit Bearing Motor...

    Description: Single-speed, 6W, 1550 RPM, shaded pole CWOSE rotation, 50/60Hz All-angle operation, continuous air over A: 4″; Agency Certification: UR; Diameter: 3-1/2″; Efficiency: 35.0%; Enclosure: TEAO; F/L Amps: 0.40; Hz: 60; Insulation Class: B; Mfg. #: 65311; Mounting: Single Foot Pad; NEMA Frame: Non-Std.; Phase: Single; Rot.: CWOSE; RPM: 1550; Service Factor: 1.00; Shaft Diam.: 1/4″-20 Thd; Shaft Length: 1/2″; Speeds: 1; Std. Mount. Pos.: All Angle; Thermal Protection: Impedance; Type: Shaded Pole; Volts: 115; Watts: 6; Wt. Lbs.: 3.0;

  • Direct Drive Blower Motor S88-585 (Mfg# D970)

    Direct Drive Blowe...

    Description: 3-speed, PSC, sleeve bearing. 1075 RPM, 3 speed, resilent mounting Rotation: Plug reversible, capacitor not included Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 40; Bearing Type: Slv; Capacitor to Match: G21-909; Diameter: 5-5/8″; Efficiency: 65.0%; Enclosure: OPEN; F/L Amps: 4.00; HP: 3/4-1/3; Hz: 60; Insulation Class: B; Mfg. #: D970; Mounting: Resilient; NEMA Frame: 48; Phase: Single; Rot.: Rev.; RPM: 1075; Service Factor: 1.00; Shaft Diam.: 1/2″; Shaft Length: 5-1/2″; Speeds: 3; Thermal Protection: Auto; Type: PSC; Volts: 277; Wt. Lbs.: 17.8; Applications: Used for fan coils, condenser fans and other air-moving applications |Designed for a broad range of …

  • Direct Drive Blower Motor S88-903 (Mfg# D727)

    Direct Drive Blowe...

    Description: 48 frame, 3-speed 1075 RPM, sleeve bearing Reversible rotation, open enclosure A: 4-1/2″; Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 40; Bearing Type: Slv; Capacitor to Match: G21-930; Diameter: 5-5/8″; Efficiency: 65.0%; Enclosure: OPEN; F/L Amps: 5.90; HP: 1/3-1/5; Hz: 60; Insulation Class: B; Mfg. #: D727; Mounting: Resilient/Thru Bolts; NEMA Frame: 48; Phase: Single; R: 4-13/16″; Rot.: Rev.; RPM: 1075; Service Factor: 1.00; Shaft Diam.: 1/2″; Shaft Length: 6″; Speeds: 3; Thermal Protection: Yes; Type: PSC; Volts: 115; Wt. Lbs.: 14.0; Applications: Ideal replacements for blowers in direct drive furnaces, air conditioners and exhaust fans Features: PSC |Open …

  • Condenser Fan Motor S89-126 (Mfg# 1873)

    Condenser Fan Moto...

    Description: 48 frame, 825 RPM Reversible rotation, 1-speed, SAB bearing All-angle mounting A: 4-1/16″; Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 60; Bearing Type: SAB; Capacitor to Match: G21-930; Diameter: 5-5/8″; Efficiency: 60.0%; Enclosure: TEAO; F/L Amps: 1; HP: 1/6; Hz: 60; Insulation Class: B; Mfg. #: 1873; Mounting: Stud; NEMA Frame: 48; Phase: Single; Rot.: Rev.; RPM: 825; Service Factor: 1.00; Shaft Diam.: 1/2″; Shaft Length: 6″; Speeds: 1; Std. Mount. Pos.: All Angle; Thermal Protection: Auto; Type: PSC; Volts: 208-230; Wt. Lbs.: 12.0; Applications: Replaces motors in units by Carrier/Bryant and others Features: 60°C ambient, thermally protected|Flat end …

  • Replacement for Magic Chef/Armstrong Condenser Fan Motor S88-858 (Mfg# 0MC6517)

    Replacement for Ma...

    Description: Single-speed, PSC motor for Magic Chef 2-ton condenser fan units Open ventilated on shaft end as is the original motor Sleeve bearings Replaces Magic Chef #35035B001, F42B59A01, CJK15, CTK18, CJK24, CJK30 and CJK36; Westinghouse #322P859; and Magnetek #DE3L038 A: 4-15/16″; Agency Certification: UR/CSA; Ambient Operating Temp. (Celsius): 40; Bearing Type: Slv; Capacitor to Match: G21-930; Diameter: 5″; Efficiency: 65.0%; Enclosure: OAO; F/L Amps: 1.50; HP: 1/5; Hz: 60; Insulation Class: B; Mfg. #: OMC6517; Mounting: Thru-bolt; NEMA Frame: 42; Phase: Single; Rot.: CWOSE; RPM: 1075; Service Factor: 1.00; Shaft Diam.: 1/2″; Shaft Length: 3-3/8″; Speeds: 1; Std. Mount. Pos.: …